          GasAlert Micro 5™ 5-Gas Detector Features & Specifications

Honeywell GasAlert Micro 5 5-gas detector with pump attached
GasAlert Micro 5 with Pump Attached

Honeywell Generation 2 pump with visible integral filter

The GasAlert Micro 5 simultaneously monitors and displays up to five potential atmospheric hazards including oxygen, combustibles and a range of toxic gases.

  • Measure up to five atmospheric hazards concurrently
  • Displays real-time gas concentrations readings for up to four gas hazards including hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gases (%LEL & % by volume)
  • Audible, visual vibrating alarms alert users to unsafe conditions while downloadable datalogging provides exposure reporting.
  • Rapidly switch from diffusion to pump mode in the field
  • Fully customizable to suit any application with wide range of user options
  • Two power options: AA alkaline or rechargeable hot-swappable battery packs
  • Dust and water resistant design with IP 65/67 rating
  • Rugged and durable, with a built-in concussion-proof boot
  • Visual, audible and vibrating alarms
  • Multi-language support in English, French, German, Spanish and Portuguese
  • Automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station


                        Download GasAlert Micro 5 Literature

 

IQ Force Configurations Page Link

GasAlert Micro5 Specifications

Size 5.7 x 2.9 x 1.5 in. / 14.5 x 7.4 x 3.8 cm
Weight 13.1 oz. / 370 g


Certification and Approvals

  • UL: Class I, Division 1, Groups A,B,C,D
  • American Bureau of Shipping - Toxic& PID models
  • CE Ex II 1 G,
  • CE Ex II 2 G - IR model only
  • CA EX ia IIC T4
  • UIECEx: Ga Ex ia IIC T4
  • BR-EXIA IIC T4

    See literature for latest certifications.\
Environmental Ratings

Normal Operating: -4° to 122° F (-20° to 50° C)
Humidity: 10% to 100% non-condensing

Alarms High, Low, TWA, STEL, OL (over limit)
Audible Alarms Multi-tone rated at 95 dBA at one foot (30cm)
Vibrating Alarm Standard
Pump Optional, Sample from up to 66 ft / 20m
Datalogger Datalogger capable of 1 year of continuous data with user configurable intervals
IQ Management System Fully compatible. Supports alarm event e-mail, person and location assignment functions. Able to be docked with or without pump attached.
Battery Alkaline: (3) AA Disposable Batteries
Rechargeable: Li-Po (Lithium Polymer) battery pack
Battery Life/ Run Time

Alkaline:         20 hours at 68 °F (20°C)
Rechargeable: 20 hours at 68 °F (20°C)

Sensors

O2, LEL, CO, H2S, SO2, PH3, NH3, NO2, HCN, Cl2,ClO2, O3

PID Model: PID for volatile organic compound (VOC) monitoring, H2S, CO, O2, SO2, PH3, NH3, NO2, HCN, Cl2, ClO2, and LEL.

IR Model: CO2 IR sensor, H2S, CO,O2, SO2, NH3, O2 & LEL

Warranty
With exceptions

Full 2 year warranty including sensors
Note: 1 year warranty only on NH3, Cl2, ClO3, O3 and PID Lamp.

User Options

Confidence/ compliance beep
Set STEL interval
Set TWA interval
Sensor on/off
Latching alarms
Safe display mode
Stealth display mode
Adjust clock
Set datalogger rate
Passcode protection
Correction Factor Libraty (LED/PID)

Fast pump
Combustible gas measurement (% LEL or % by volume methane)
O2 auto calibration on start-up
Force Calibration
Force bump
Auto-zero on start-up
Automatic backlight
Sleep mode
User-definable calibration gas concentration
Language choices (5)e


GasAlert Micro5 Configurations  

Part Number
Quattro- Sensors Installed
M5-XWSY-R-D-D-Y-N-00 % LEL, O2, H2S, CO, SO2 - lithium polymer - yellow housing
M5-XWSY-R-P-D-Y-N-00 % LEL, O2, H2S, CO, SO2 - lithium polymer and pump - yellow housing
M5-XWAY-R-D-D-Y-N-00 % LEL, O2, H2S, CO, NH3 - lithium polymer battery - yellow housing
M5-XWAY-R-P-D-Y-N-00 % LEL, O2, H2S, CO, NH3 - lithium polymer battery and pump - yellow housing
M5-XWCY-R-D-D-Y-N-00 % LEL, O2, H2S, CO, Cl2 - lithium polymer battery - yellow housing
M5-XWCY-R-P-D-Y-N-00 % LEL, O2, H2S, CO, Cl2 - lithium polymer battery and pump - yellow housing
M5-XW0Y-A-P-D-Y-N-00 % LEL, O2, H2S, CO - alkaline batteries and pump - yellow housing
M5-XW0Y-R-D-D-Y-N-00 % LEL, O2, H2S, CO - lithium polymer battery - yellow housing
M5-XW0Y-R-P-D-Y-N-00 % LEL, O2, H2S, CO - lithium polymer battery and pump - yellow housing
Detectors ship with specific sensor(s), stainless steel alligator clip and concussion-proof housing, rechargeable battery pack or alkaline pack with three AA batteries, charging adaptor (with rechargeable battery option), screwdriver, calibration/test adaptor and hose, manual and multi-language CD manual
For Black Housing Change the "Y" in the part number to "B"
For PID and IR instruments contact us for part numbers

GasAlert Micro 5 Accessories

Part # Description
MK-CK-DLGasAlert Micro 5 Deluxe Confined Space Kit GasAlert Micro5 Series Deluxe Confined Space Kit includes manual aspirator kit, calibration cap, 1.0 LPM regulator, sampling probe with holster, detector holster, five spare auxiliary filters and three spare quick connect fittings - Note: Dector & Calibration gasses sold separately.

M5-CK-CC

Carrying Case for GasAlert Micro 5 Series - with foam and lid insert from M5-CK-DL kit - Note: Detector and calibration gas sold separately.
GA-SPAK SamplerPak motorized sampling pump kit with alkaline batteries
QA-AS02 Manual aspirator pump
M5-TC-1 Replacement test cap and hose
M5-PUMP Integral motorized pump kit with visible integrated filter, yellow - Includes motorized pump cover, 1 ft. / 30 cm sample probe with hydrophobic barrier (water trap) and particulate filters, 5 ft. / 1.5 m sampling tubing, three spare particulate filters and one spare water trap filter.
M5-PUMPB Integral motorized pump kit with visible integrated filter, black - Includes motorized pump cover, 1 ft. / 30 cm sample probe with hydrophobic barrier (water trap) and particulate filters, 5 ft. / 1.5 m sampling tubing, three spare particulate filters and one spare water trap filter.
M5-QCONN-K1 Auxiliary pump filter compatible with hose
M5-BAT0501 Alkaline battery pack, yellow*
M5-BAT0501B Alkaline battery pack, black*
M5-BAT08 Rechargeable battery pack - yellow *
M5-BAT08B Rechargeable battery pack - black *
GA-NS-1 Neck strap with safety release
GA-LY-1 Short strap (6 in. / 15.2 cm)
GA-ES-1 Extension strap (4 ft. / 1.2 m)
GA-CH-2 Chest harness
GA-FLOAT Sampling float
*Note: Battery packs and chargers should be used with the new version GasAlertMicro 5 Series gas detectors (red circuit boards).
 

 

    MicroDock II ™ Automatic Bump Test, Calibration & Data Download Station

Gas Alert Micro Dock System

Micro Dock Bump Test/Calibration Station

Take Command of Instrument Testing & Data

Reduce your calibration gas use by up to 60% and your labor expenses by cutting down on the time needed to perform calibrations. Downtime is reduced as auto calibration is finished in two minutes. Through the networkable dock and system software, you obtain full visibility to information on detector performance, compliance and trending including:

  •  Alarms
  •  Gas exposure levels
  •  Safety incident history
  •  Sensor health status
  •  Calibration and bump test results
  •  Cal gas consumption
  •  Battery usage
  •  Dock station data
  •  Full alarm function testing (audio, visual, vibration)
  •  Security settings
  •  And other instrument details

 

Part Number
MicroDockII Bump Test/Calibration Station Configurations
DOCK2-2-1C1K-00-G MicroDock II automatic test and calibration system base station and GasAlertMicro 5 Series docking module (charging) with charging cable
DOCK2-2-1J-00-G MicroDock II automatic test and calibration system base station and GasAlertMicro 5 Series docking module (non-charging)
DOCK2-0-1K-00-G GasAlertMicro 5 Series MicroDock II docking module (charging), no charging cable
DOCK2-0-1N-00-G GasAlert Micro 5 Series docking module without charging cable

Terms for Instrument and Accessory Returns:
NOTE: Any returns will incur the Honeywell 25% restocking fee on the list price of the item. To return any instruments or accessories you must request a Return Authorization number prior to returning anything to the factory for credit. This Return Authorization number must be prominently displayed on the outside of the shipping box. All products returned to Honeywell must be sent freight pre-paid, in new condition and in the original cartons with all unopened software, accessories and manuals. The sender is responsible for any carrier loss or damage.

WARNING! Honeywell equipment should only be used in conjunction with the manufacturer's instructions.
Failure to follow such instructions could result in serious injury or fatality.

Green BackToTop Lin

 

IQ Force Configurations Page Link

Return to Brandt Instruments
For more information  Email Mail
Brandt Instruments, Inc. 
    18568 Oak Grove Parkway 
    Prairieville, LA  70769 
1-800-337-6291  
Phone: 225-673-6776
    Fax: 225-673-6725
 

Visa, MC, AmEx, Discover Cards

Copyright © 2002-2016 Brandt Instruments, Inc.

Notice: This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures. Brandt Instruments, Inc. reserves the right to make any changes to information, features, and specifications of any product without notice. Brandt Instruments, Inc. has made every effort to ensure the accuracy of information displayed on this web site, however, Brandt Instruments, Inc. is not responsible for typographical errors appearing on this web site. Price and availability information is subject to change without notice.