Otis Instruments OI-6000K
Single Channel Fixed Gas Detection System



home otis instruments fixed point detectors OI-6000K Otis Instruments Single Channel Fixed Gas Detection


 

 

Otis Instruments OI-6000K  Fixed Single Gas Detector_SingleLight&TriLite

OI-6000K Single Strobe
Integrally Mounted Sensor

TriLite Available



Otis Instruments OI-6000K Twin Red & Amber Strobes with Remote Sensor

OI-6000K
Twin Red & Amber Strobes
& Remote Sensor


Otis Instruments OI-6000K  Fixed Single Gas Detector_TowerLight

OI-6000K with Tower Strobe
& Remote Sensor

Otis Instruments OI-6000K fixed gas detector provides single point protection in less than 5 minutes – just plug it in, check the calibration and be protected! The OI-6000K can be used as a stand alone self contained monitor, use a remote sensing head or be part of a transmitter in a larger system.

OI-6000K systems are designed to provide continuous monitoring for a variety of common atmospheric hazards including oxygen deficiency and/or enrichment, combustible gases and vapors, and specific toxic contaminants such as:

Ammonia (NH3) Formaldehyde (CH2O) Oxygen (O2)
Carbon monoxide (CO) Hydrogen Cyanide (HCN) Ozone (O2)
Chlorine (Cl2) Hydrogen Fluoride (HF) Sulfur dioxide (SO2)
Combustible gas (LEL) Hydrogen Sulfide (H2S) Phosphine (PH3)
Fluorine (F2) Nitrogen Dioxide (NO2) PID sensor for VOC detection & many others

Available with Electro-Chemical (EC), Catalytic Bead, PID or Infrared (IR) sensor elements. Sensors may be integrally mounted to the controller housing, or linked by wire or wirelessly with a WireFree™ system to the controller.    

Best of all, the the OI-6000K offers the flexibility to choose single, twin color or tower of high-intensity strobes, integrated 102 db audio alarm, real time LCD readout…..all in a sleek, tough NEMA 4X housing.


OI-6000K Technical Specifications

Case Stahlin fiberglass with clear window, wall mount
Note: Type 4X enclosures are intended for indoor and outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose-directed water; and to be undamaged by the formation of ice on the enclosure.
UL/cUL 50
NEMA 250
CSA Std. C22.2
IEC 60529
File E64358 Type 1, 3, 3s, 4X, 12, 13
Type 1, 3, 3s, 4X, 12, 13
File LR069014 Type 1, 3, 3s, 4X, 12, 13
IP66 / NEMA4X
Sensor Types Electro-chemical, catalytic bead, PID or Infrared.
Display Graphical LCD, sunlight readable
LED back-light, 102 x 64 resolution
Flammability Rating UL94-5V
Window Temperature Range (-26F to +170F) (-32C to +76C)
Window Flammability UL94-HB
Self Extinguishing Non-halogenated, non-flame propagating
Interface Three push buttons (MENU, ADD, SUB)
Dimensions Controller: 8" x 8" x 4"
Weight 5.5 - 6.0 lbs (Varies by options selected)
Power +12-35 Volts DC (with terminal connectors for the DC wires on the circuit board)
110/240 Volts AC (with cord grips and cable)
Power Source 110/220 VAC or 12-24 VDC.
Current Draw 1.25 A (max @ 24 VDC)
Relays 5 Amp relays with 4 Amp fuses
Signal Output 4-20 mA; RS-485 Modbus. Can be customized to offer relay and radio (900MHz or 2.4GHz) options.
Temperature Range (-76F to +274F) (-60C to +134C)
Wiring: Comes standard with cord grips and cable. Optional AC power cord
Order cables for remote sensor housing from 10' to 100'.
Warranty Hardware: One year (Limited)
Sensor: varies with sensor type


Each OI-6000K system includes the controller with all standard alarms, relays and electronics installed in a non explosion-proof fiberglass housing, and sensor. Custom configurations & wireless systems are available.

Note: Cable, conduit, wire and other components necessary to connect remotely located sensors with the instrument controller are not included. Order the cable separately

Otis OI-6000K Brochure

   OI-6000K Manual

 

.

OI-6000 System Ordering Information

OI-6000K System

OI-6000K System
Description
Range
Resolution
OI-6000K-EC-O2-AC-X-R O2 Oxygen 0 - 25% 0.1 %
OI-6000K-CB2-LEL-AC-X-R LEL combustible 0 - 100% LEL 1.0 % LEL
OI-6000K-IR-LEL-AC-X-R LEL combustible 0 - 100% LEL 1.0 % LEL
OI-6000K-EC-CO-AC-X-R CO, Carbon monoxide 0 - 1000 ppm 1.0 ppm
OI-6000K-EC-H2S-AC-X-R H2S, Hydrogen sulfide 0 - 200 ppm 1.0 ppm
 
OI-6000K-EC-NH3-AC-X-R NH3, Ammonia 0 - 100 ppm 1.0 ppm
OI-6000K-EC-Cl2-AC-X-R Cl2, Chlorine 0 - 50 ppm 0.1 ppm
OI-6000K-EC-SO2-AC-X-R SO2, Sulfur dioxide 0 - 75 ppm 0.1 ppm
OI-6000K-EC-PH3-AC-X-R PH3, Phosphine 0 - 20 ppm 0.1 ppm

Note - For Additional Configurations See Sensor List Below:

-AC-X-R Use "R" for red strobe, "A" for amber strobe or "G" for green. For instance GAR would be a tower configuration of green, amber, & red strobes

-AC-X-A Replace the "X" with length of remote sensor cable from 10-100'


** Cable for Remote Sensor is ordered separately.

NOTE: If the sensor is mounted in a potentially explosive environment, sensor must be connected to the base unit following NEC guidelines for hazardous locations.

OI-102WEP-X Explosion-Proof Horn

OI-102WEP-X Explosion-Proof Horn

5 or 7-Pin Remote Sensor Kit

5 or 7-Pin Remote Sensor Kit

For additional accessories and options go to the Accessories page

 
  Otis Instruments OI-6000K Replacement Sensors

Part # Description Range Resolution
Accuracy
OI-254-O2 O2, Oxygen 0 - 25% 0.1%
± 2%
OI-120-NP-17SHM LEL, Combustible Gas
(Catalytic Bead) (OI-6000 only)
0 - 100% LEL 1.0% Increments
±1%
OI-140-NP-IR-LEL LEL, Combustible Gas (Infrared)
(OI_6000 only)
0 - 100% LEL 1.0% Increments
± 2%
OI-254-CO CO, Carbon Monoxide 0 - 999 ppm 0.1 to 10 ppm, 1 ppm thereafter
± 2%
OI-140-IR-CO2 CO2, Carbon Dioxide
(OI-6000 only)
0 - 5% 0.1 ppm
± 2%
OI-254-H2S H2S,  Hydrogen Sulfide 0 - 100 ppm 0.1 to 10 ppm, 1 ppm thereafter
± 2%
OI-254-H2S-2K H2S, Hydrogen Sulfide (Ext.Temp) 0 - 100 ppm 0.1 to 10 ppm, 1 ppm thereafter
± 2%
OI-254-NH3 NH3, Ammonia 0 - 100 ppm 0.1 to 10 ppm, 1 ppm thereafter
± 5%
OI-254-NH3A NH3, Ammonia (Ext) 0 - 1000 ppm 0.1 to 10 ppm, 1 ppm thereafter
± 5%
OI-254-Cl2 Cl2, Chlorine 0 - 10 ppm 0.1 ppm
± 5%
OI-254-F2 F2, Florine 0-1 ppm 0.01 ppm
± 5%
OI-254-CH2O CH2O, Formaldeyde 0-10 ppm 0.01 ppm
± 2%
OI-254-H2 H2, Hydrogen 0- 4% 0.1 ppm
± 10%
OI-254-HCl HCN, Hydrogen Chloride 0- 30 ppm 0.1 ppm
± 5%
OI-254-HCN HCN, Hydrogen Cyanide 0- 30 ppm 0.1 ppm
± 5%
OI-254-HF HF, Hydrogen Floride 0 - 10 ppm 0.1 ppm
± 10%
OI-254-NO2 NO2, Nitrogen Dioxide 0-50 ppm 0.1 ppm
± 5%
OI-254-O3 O3, Ozone 0-100 ppm .1 to 10 ppm, 1 ppm thereafter
± 2%
OI-254-SO2 SO2, Sulfur Dioxide 0 - 20ppm .1 to 10 ppm, 1 ppm thereafter
± 2%
OI-254-PH3 PH3, Phosphine 0 - 20 ppm 0.1 ppm
± 2%
OI-254-PID-A1 PID, Photo Ionization Detector for volatile organic compounds (VOCs) (OI-6000 only) 10, 20 or 50 ppm 0.1 to 10 ppm, 1 ppm thereafter
± 5%
OI-254-AH PID, Photo Ionization Detector for volatile organic compounds (VOCs) (OI-6000 only)

1000 or 2000 ppm

0.1 to 10 ppm, 1 ppm thereafter
± 3%

Note: Other gases and ranges available
. Contact us for additional information


Green_Back-To-Top_Icon


WARNING! Otis Instruments equipment should only be used in conjunction with the manufacturer's instructions.
Failure to follow such instructions could result in serious injury or fatalities.

 

Return to Brandt Instruments
For more information  Email Mail
Brandt Instruments, Inc. 
    18568 Oak Grove Parkway 
    Prairieville, LA  70769 
1-800-337-6291  
Phone: 225-673-6776
    Fax: 225-673-6725
 

Visa, MC, AmEx, Discover Cards

Copyright © 2002-2017 Brandt Instruments, Inc.