Brandt Intruments: Sperian Instruments, Biosystems Gas Detectors,now Honeywell Analytics, MultiPro, ToxiPro, PhD6, calibration gas,, PosiChek3 SCBA tester

Representing Biosystems by Honeywell Analytics

Biosystems, Sperian Instruments, Honeywell, gas detectors, MultiPro, PhD6, ToxiPro, ToxiLTD, IQ Docking Stations, PosiChek3 SCBA Testing, calibration gas

Honeywell Biosystems
Toxi IQ Express Docking Station

for ToxiPro® Single Gas Detectors
From Sperian Instruments Now Part of Honeywell Safety

Automated Dock for Bump Testing, Calibration
Datalogging & Detector Diagnostics


home biosystems index Biosystems IQ Express Docking Station by Sperian Biosystems now part of Honeywell Safety

Biosystems Index
.. Single Gas Portables..
.. Multi-Gas Portables

..   ..MultiPro
...   .MultiVision
...   .PhD6
...   .Cannonball3
.. Fixed Point Systems
.. Air Purification Panel
. .Respirator Test Bench
. .Cal Gas & Accessories
. .Application Notes

Honeywell Sperian Biosystems Toxi IQ Express Docking Station Automatic Calibration Station on Shop Bench

Toxi Pro IQ Express
Automatic Calibration
& Bump Test Station

Assured Safety and Compliance in under 20 seconds*

 

Biosystems Toxi IQ Express Docking Station is a fully automated bump test, calibration, meter diagnostics and data download center for the ToxiPro single gas detectors.

 

It can reduce calibration gas use by up to 60% and reduce labor expenses by cutting down on the time needed to perform calibrations.

 

Simply place the meter into the dock, the Toxi IQ Express does the rest. The station identifies the instrument then performs a quick battery test before moving on to a bump test. If the detector fails the bump test, the IQ Express automatically performs a full span calibration of the detector, also without further intervention from the user.

 

Total processing time with a full span calibration is still under one minute*.

 

Once the instrument passes the bump test or span calibration, the IQ Express automatically tests the audible, visible and vibrating (if available) alarms before downloading instrument data.

 

Once all the tests are passed, the IQ Express Dock will show "Ready" no the display signifying that the detector is ready to go.

 

*O2, CO and H2S Models.  Other sensor types may take longer.

 

Biosystems Toxi IQ Express Docking Station™ Features

Automated Tests
Configuration Options
  • Checks more than 8 different performance functions
  • Instrument identification
  • Battery test
  • Alarm tests (audible, visible, vibrating
  • Ready / fault indication
  • Bump test in under 30 seconds
  • Calibration (if needed) in about 1 minute
  • Maintains records of instrument and calibration data
  • Provides clear, easy-to-read reports
  • Standalone calibration station
  • Links up to 4 docks on a single gas supply
  • Connect to PC via USB or Ethernet for enhanced control over calibration and data acquisition during testing (optional)
  • Ethernet capable docks can send e-mail to a specified address when a fault is detected
  • Docking station software allows the user to customize the instrument's settings and calibration gas setup
  • View live status of bump and calibration testing
   

Standard and Enhanced Versions

The IQ Express can be configured in two ways: 

Standard versions of the IQ Express Dock are capable of processing instruments containing the following sensor types: O2, CO, and H2S. 

Enhanced versions of the IQ Express Dock are capable of processing instruments with all of the sensors listed above plus ToxiPro instruments with SO2, Cl2, NO2, NH3, HCN and PH3 sensors.

ToxiPro, ToxiLtd IQ Express Four Monitor Automated Test Station

Automated 4-Station Configuration
   

                                        Biosystems IQ Express Docking Station Ordering Information

Part Number Description
54-46-9100 IQ Express Docking Station: Enhanced Version (For ToxiPro and ToxiLTD Instruments configured for O2, CO, H2S, SO2, Cl2, NO2, NH3, HCN or PH3) Includes Software, Installation Disks and Manuals.
54-46-9100N IQ Express Docking Station: Ethernet Ready Enhanced Version (For ToxiPro and ToxiLTD Instruments configured for O2, CO, H2S, SO2, Cl2, NO2, NH3, HCN or PH3) Includes Software, Installation Disks and Manuals.
54-46-8000 IQ Express Mounting Bracket (not powered). Includes tubing and magnetic hardware.
12-061 Demand flow regulator* (One required for each cylinder of gas)
54-05-001 Calibration gas tank holder
 
* Note:
Demand flow regulators, calibration gas and accessories sold separately


WARNING!
Honeywell Analytics - Biosystems equipment should only be used in conjunction with the manufacturer's instructions.
Failure to follow such instructions could result in serious injury or fatalities.

Honeywell Sperian Biosystems Toxi IQ Express Docking Station Automatic Calibration Station with ToxiPro Detectors
Toxi IQ Express with ToxiPro Single Gas Detectors

Terms for Instrument and Accessory Returns:
NOTE: Any returns will incur the Honeywell 25% restocking fee on the list price of the item. To return any instruments or accessories you must request a Return Authorization number prior to returning anything to the factory for credit. This Return Authorization number must be prominently displayed on the outside of the shipping box. All products returned to Honeywell must be sent freight pre-paid, in new condition and in the original cartons with all unopened software, accessories and manuals. The sender is responsible for any carrier loss or damage.

 

Return to Sperian - Biosystems Product Information Page

Return to Brandt Instruments
For more information  Email Mail
Brandt Instruments, Inc. 
    18568 Oak Grove Parkway 
    Prairieville, LA  70769 
1-800-337-6291  
Phone: 225-673-6776
    Fax: 225-673-6725
 

Visa, MC, AmEx, Discover Cards